• For designs 01/03
  • Consisting of two sets per sales unit
  • For two transformers each

with stranded wire 150 mm and extended plug

for SlimBox, SlimBox-E and SlimBox-Pro

for SlimBox, SlimBox-E and SlimBox-Pro

for SlimBox and SlimBox-Pro

  • With NTC inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 350 VA
  • Complies with medical standard EN 60601-1:2006/A1:2013 incl. Appendix ZZ
  • Developed & produced according to EN ISO 13485
  • With NTC inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 700 VA
  • Complies with medical standard EN 60601-1:2006/A1:2013 incl. Appendix ZZ
  • Developed & certified according to EN ISO 13485
  • With NTC inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 1000 VA
  • Complies with medical standard EN 60601-1:2006/A1:2013 incl. Appendix ZZ
  • Developed & produced according to EN ISO 13485
  • With electronic inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 350 VA
  • Conforms to medical standard IEC 60601-1:2005/A1:2012
  • Developed & produced according to EN ISO 13485
  • With electronic inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 700 VA
  • Conforms to medical standard IEC 60601-1:2005/A1:2012
  • Developed & produced according to EN ISO 13485
  • With electronic inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 1000 VA
  • Conforms to medical standard IEC 60601-1:2005/A1:2012
  • Developed & produced according to EN ISO 13485
  • With electronic inrush current limiting
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 1700 VA
  • Conforms to medical standard IEC 60601-1:2005/A1:2012
  • Developed & produced according to EN ISO 13485
  • UL approved, with NTC for worldwide use
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 850 – 1000 VA (3 taps)
  • Complies with the currently valid medical standard EN 60601-1:2006/A1:2013 incl. Appendix ZZ
  • Developed & produced according to EN ISO 13485
  • With NTC inrush current limiting
  • Compact & easy to operate, e.g. can only be combined with a single unit
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 50 VA
  • Developed & certified according to EN ISO 13485
  • Compact & easy to operate, e.g. can only be combined with a single unit
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 100 VA
  • Developed & produced according to EN ISO 13485
  • Compact & easy to operate, e.g. can only be combined with a single unit
  • Safe galvanic isolation from patient environment and power supply network
  • Optimal protection for patients, supply personnel and equipment
  • Rated power: 200 VA
  • Developed & produced according to EN ISO 13485
  • Pulse Code Modulation Long Distance Transmitter
  • for safe galvanic isolation
  • Project planning, development, construction
  • Production, assembly & electrical installation
  • Service
  • Deutronic Certified Partner
  • Wide range of DC/DC converters, power supplies, battery chargers and many more for industrial applications from our partner Deutronic

PCM – Fernleitungsübertrager

  • Safety and isolating transformers according to EN 61558-2 / VDE 0570 with ENEC and UL test marks
  • Max. Ambient temperature ta = 40°C / temperature class B (130°C)
  • Very low magnetic stray field
  • High efficiency
  • Toroidal transformer without mounting accessories
  • Safety and isolating transformers according to EN 61558-2 / VDE 0570 with ENEC and UL test marks
  • Max. Ambient temperature ta = 40°C / temperature class B (130°C)
  • Very low magnetic stray field
  • High efficiency
  • Toroidal transformer without mounting accessories
  • Safety and isolating transformers according to EN 61558-2 / VDE 0570 with ENEC and UL test marks
  • Maximum ambient temperature ta = 60°C / temperature class B (130°C)
  • Temperature switch 120°C integrated (automatically resetting)
  • Very low magnetic stray field
  • Very high efficiency
  • Toroidal transformer potted on mounting plate with central through hole
  • Safety and isolating transformers according to EN 61558-2 / VDE 0570 with ENEC and UL test marks
  • Maximum ambient temperature ta = 60°C / temperature class B (130°C)
  • Temperature switch 120°C integrated (automatically resetting)
  • Very low magnetic stray field
  • Very high efficiency
  • Toroidal transformer potted on mounting plate with central through hole